We have a new biohazard waste can. It is intended for the disposal of any biohazards, full sharps containers, etc. It is currently placed in the apparatus bay next to the med cabinet. When the can is full and needs to be picked up we will need to contact Western Oregon Waste. We need to be aware of weight as well as fullness of the container, there is a 50 lb. maximum on the full weight.
Wednesday, November 30, 2011
Biohazard waste
Station Tour
B – Shift:
I scheduled a station tour for the Oregon Virtual Academy on January 13, 2012 from 11am-12pm for approximately 30 kids and parents. Grades Kindergarten to 5th grade. An Emily Sugar will be contacting us to confirm the number of kids and parents attending the station tour. Initial contact person is: Sara McAfee at 503-307-7946.
Monday, November 28, 2011
American Red Cross Trailer
Bob Peto with the American Red Cross will be in tomorrow, Tuesday, November 29th to inventory the Red Cross trailer out back.
Tuesday, November 22, 2011
Breathing treatment medications
Hello All,
Say I re-adjusted our medications for breathing treatments in both ALS kits today plus updated the EMS check-sheet for both 2522 and 2541 EMS kits. The updates reflect what is current in our standing orders at this time. Please do not use any Albuterol Sulfate as I ordered it in error, Xopenex or Levalbuterol is what our standing orders call for. Thanks Aaron B
Sunday, November 20, 2011
Wednesday, November 16, 2011
FW: Monsoon master stream nozzle
Subject: RE: Monsoon master stream nozzle
Date: Tue, 15 Nov 2011 13:26:05 +0000
Date: Tue, 15 Nov 2011 13:26:05 +0000
Mr Hansen-
Good morning! Looking at the photo of your Master 2000 it has an operating pressure of 100 psi, so within the flow range of the nozzle base nozzle pressure should be about 100 psi.(back pressure)
Can you verify that your nozzle has all the parts indicated above, most specifically the poppet, control spring, and the square seal shown on the piston? Also, looking from the inlet side there is a filter screen in the center of the nozzle, make sure this is not plugged. If all of these items are in place and in good order I am unsure why the nozzle would be causing your pump to cavitate. Is it possible that there is a recirculation valve or PRV open somewhere causing the water to taken another path? What are engine pressure, residual pressure, etc… when flowing this device. Is this from Draft or a pressurized source? Any additional information you can provide on your set up is a great help.
Can you please provide the serial number of the units, it will be configured as TFTM- then six digits.
Thank you
Doug Heller
Task Force Tips, Inc.
Technical Service Coordinator
TFT Main Ph: 800.348.2686
Direct Service Ph: 800.854.6864
From: Lenard Hansen [mailto:chieflenard@hotmail.com]
Sent: Monday, November 14, 2011 10:37 PM
To: TFT Service and Technical Support
Subject: Monsoon master stream nozzle
Sent: Monday, November 14, 2011 10:37 PM
To: TFT Service and Technical Support
Subject: Monsoon master stream nozzle
We have a couple of monsoon 300-2000gpm nozzles. When pumped on the master stream device, the pump will start to cavitate like there's no "back pressure" on the nozzle. In other words, just like an open hose end without a nozzle. When we look at the tip, we don't find any markings that would indicate a desired pressure that we read on brochures from TFT. A picture is enclosed to help identify the type of nozzle. Do you have any suggestions or answers for us?
Lenard
Astoria Fire & Rescue
555 30th Street
Astoria, OR 97103
Lenard
Astoria Fire & Rescue
555 30th Street
Astoria, OR 97103
Tuesday, November 15, 2011
2523 CAFS
We ran some tests on 2523 yesterday and found that the CAFS system is not operating. We will need to order a new control box.
Subscribe to:
Posts (Atom)

